Show simple item record

dc.creatorYee Foo, Swee 41731, autor. aut
dc.creatorCuppett, Susan 41732.
dc.creatorSchlegel, Vicki 41733.
dc.creatorDepartment of Food Science and Technology, University of Nebraska, Lincoln, Nebraska, USA 41734.
dc.date©2006
dc.descriptionThe feasibility of applying methods developed by Safety Associates, Inc., to monitor oil degradation products, including malondialdehydes (AldeSafeTM), FFA (FASafeTM), and peroxides (PeroxySafeTM), in fresh and heat-abused deep-fat frying oil was evaluated. Based on performance qualification studies, the AldeSafe method was the most suitable SafTestTM assay for monitoring the quality of frying oil because of its high accuracy, precision, linearity, and reproducibility, and low detection/quantitation limits. A strong correlation (r 0.924) between the AldeSafe method and its counterpart, AOCS Official Method Cd 19-90, also supported the suitability of the SafTest method for monitoring oil quality. Moreover, the FASafe method had a moderately strong relationship with AOCS Official Method Ca 5a-40 (r 0.761). Our studies suggest that this test can be applied for monitoring frying oil; however, certain method performance limitations must be considered for routine analysis purposes. In contrast, the PeroxySafe method probably should not be used to monitor heat-abused oil without further development because of high variability, low accuracy, and low correlation (r 0.062) with the AOCS Official Method Cd 8-53 assay.
dc.descriptionThe feasibility of applying methods developed by Safety Associates, Inc., to monitor oil degradation products, including malondialdehydes (AldeSafeTM), FFA (FASafeTM), and peroxides (PeroxySafeTM), in fresh and heat-abused deep-fat frying oil was evaluated. Based on performance qualification studies, the AldeSafe method was the most suitable SafTestTM assay for monitoring the quality of frying oil because of its high accuracy, precision, linearity, and reproducibility, and low detection/quantitation limits. A strong correlation (r 0.924) between the AldeSafe method and its counterpart, AOCS Official Method Cd 19-90, also supported the suitability of the SafTest method for monitoring oil quality. Moreover, the FASafe method had a moderately strong relationship with AOCS Official Method Ca 5a-40 (r 0.761). Our studies suggest that this test can be applied for monitoring frying oil; however, certain method performance limitations must be considered for routine analysis purposes. In contrast, the PeroxySafe method probably should not be used to monitor heat-abused oil without further development because of high variability, low accuracy, and low correlation (r 0.062) with the AOCS Official Method Cd 8-53 assay.
dc.languageng
dc.publisher
dc.relation
dc.subjectaceite de freir
dc.subjectCalidad.
dc.subjectDegradación.
dc.titleEvaluation of SafTestTM Methods for monitoring frying oil quality.
dc.typetext


Files in this item